908 Series Commercial Steel Slope-Top Convector

  • Designed to mount on wall at sill height (or lower) and can be positioned directly on floor. End of unit can be positioned against adjacent sidewall if desired
  • Front cover fabricated from 16-gauge steel; back cover is constructed of 18-gauge steel
  • Thermal limit switch with linear type (full length) sensing bulb provides constant protection against overheating. Switch will automatically reset when normal operating temperatures are restored
  • Elements are long-life metal sheath type, anchored to allow for quiet expansion and contraction
  • Baked enamel finishes are compatible with all interior decors
  • Attractive 45° sloped top discourages use of heater as a shelf or a “step stool”
  • Units can be mounted from wall-to-wall or as discrete units in standard lengths of 28 in. to 10 ft.
  • Optional built-in controls include: thermostat; disconnect switch; transformer relay; and power relay (see specifications)
  • Accessories include complete line of matching splice sections, inside and outside corners, and blank sections
  • Pre-wired and designed for either right- or left-hand entry with connection of supply wiring from bottom, rear or end, as well as multiple wiring of adjacent heaters from one entry point
  • All internal parts are accessible by removing cover for easy service access
  • NEMA 4X model* consists of stainless steel design rated for washdown and corrosive environments

*Contact sales representative for more information on NEMA 4X models.

 

 

 

Approvals

Product Inquiry

Standard Features

ENCLOSURE: shall be constructed of a 16-gauge, furniture quality steel with reinforced, all welded construction; designed to withstand heavy-duty commercial and institutional use. The front cover shall be set at a 45° angle, discouraging the use of heater as a shelf or “step stool”. Inlet and discharge air louvers shall be stamped and integrated into the front cover for additional rigidity.

SIZE: Heaters shall have a 45° front profile with 3 ¼” width and 10″ height and available in length from 28 inches through 10 feet.

HEATING WIRING, VOLTAGES and WATTAGES: Heater voltages and wattage capacities shall be as indicated on the plans. Pre-wired and designed for either right- or left-hand entry with connection of supply wiring from bottom, rear or end, as well as multiple wiring of adjacent heaters from one entry point.

HEATING ELEMENTS: The nickel-chromium heating element wire shall be encased in a steel sheath for maximum, trouble-free element life. Aluminum fins shall be pressure bonded to the steel sheath. Elements shall be center anchored and shall float freely at each end through high-temperature Noryl bushings.

THERMAL PROTECTION: Thermal limit switch with linear type (full length) sensing bulb provides constant protection against overheating. Switch will automatically reset when normal operating temperatures are restored.

 

FINISH: Units shall be chemically treated and finished with polyester powder paint, in order to resist corrosion. A range of five or more color options will be available in order to match field aesthetics.

OPTIONAL BUILT-IN CONTROLS: Thermostats, low voltage control relays, transformer relays, and power on/off switches, may be specified for factory installation in heaters. Thermostats and power on/off switches are accessible through the grille. All internal parts are accessible by removing cover for easy service access.

OPTIONAL FIELD INSTALLED ACCESSORIES: A complete line of matching splice sections, inside and outside corners, and blank sections to create an end-to-end aesthetic design are available.

NEMA 4X models are intended for installation in areas where periodic wash-down with water is desired. The enclosure is made of stainless steel to prevent corrosion and the wiring compartment meets NEMA 4X requirements for a water tight construction. Consult factory for additional details and specifications.

All heaters and electrical accessories shall be labeled by Underwriters’ Laboratories, Inc.

 

Applications

  • Offices
  • Lobbies & Hallways
  • Stairwells

NEMA 4X Models:

  • Food Processing Areas
  • Breweries
  • Wastewater Treatment Plants
  • Swimming Pools

Closed Tank Heating

Watt Density

Percentage of Wattage

Need a quote?

We market our products through a nationwide network of representatives. Contact us today!